DEADMAN operating logic:
- motor/s with accessories
- release for manual operation
- control panel with electronics for movement control with DEADMAN operating logic. Integrated push-button panel with separate Open-Close function
- security micro-switch on pedestrian door with wireless signal transmitter
Automatic operating logic
- motor with accessories
- release for manual operation
- control panel with electronics for movement control:
- Open-Close buttons with Deadman operating logic
- Start button with automatic operation dependent on the type of programming (Open-Stop-Close-Stop-Open) or (Open-Close automatically)
- emergency stop button (blocks door operation)
- security micro-switch on pedestrian door with wireless signal transmitter
- n° 1 flashing indicator light (door moving)
- pair of external photocells for obstacle detection to be installed at 500 mm from the ground
- vertical sensitive edge positioned on one of the front doors; height to be protected 2500 mm from the ground. Wireless signal transmission device.
- Vertical sensitive edge fixed to the wall in case of obstacle at the end less than 500 mm; height to be protected 2500 mm from the ground.
Please note 1: if the height of the door is less than 2500 mm, the DEADMAN logic must be used.
Please note 2: if the installation is external, the motors cannot be safe from tampering attempts. Break-in security is still guaranteed by the Cremone bolt locking systems.